Sale!
,

Motorola XiR P8608Ex UHF ATEX Digital Two‑Way Radio | Intrinsically Safe DMR Transceiver

$729.00$1,200.00

- +

Motorola XiR P8608Ex Explosion-Proof Radio | ATEX/IECEx Certified DMR Intrinsically Safe Two-Way Radio

Product Overview

The Motorola XiR P8608Ex is a professional-grade ATEX-certified DMR digital two-way radio engineered for communication in hazardous and potentially explosive environments. As part of Motorola Solutions’ MOTOTRBO series, this intrinsically safe transceiver delivers reliable, crystal-clear digital communication where safety is paramount.

Certified to ATEX and IECEx standards for use in Zone 1 and Zone 2 hazardous areas, the XiR P8608Ex is the trusted choice for industries dealing with flammable gases, vapors, mists, and combustible dusts. From oil refineries and chemical plants to mining operations and pharmaceutical facilities, this explosion-proof radio ensures your team stays connected without compromising safety.

Built on the DMR (Digital Mobile Radio) Tier II platform, the P8608Ex offers superior audio quality, extended battery life, enhanced coverage, and advanced features that analog radios simply cannot match. Whether coordinating routine operations or responding to emergencies, the Motorola XiR P8608Ex delivers mission-critical communication you can depend on.


Why Choose Motorola XiR P8608Ex?

🛡️ ATEX/IECEx Certified for Hazardous Environments

The XiR P8608Ex carries ATEX (European) and IECEx (International) certifications, making it approved for use in:

Zone Classification Environment Type Examples
Zone 1 Areas where explosive gas/air mixtures are likely to occur during normal operations Oil platforms, refineries, chemical processing areas
Zone 2 Areas where explosive gas/air mixtures are not likely to occur, but may exist for short periods Storage areas near hazardous zones, ventilated areas
Zone 21 Areas where combustible dust clouds are likely to occur occasionally Grain handling, coal processing, pharmaceutical manufacturing
Zone 22 Areas where combustible dust clouds are not likely, but may occur briefly Areas adjacent to dust-producing operations

Certification Details:

  • ATEX Directive: 2014/34/EU
  • Equipment Group: II
  • Category: 2G (Gas) / 2D (Dust)
  • Protection Type: Intrinsically Safe (Ex ia)
  • Gas Group: IIC (Hydrogen, Acetylene compatible)
  • Temperature Class: T4 (≤135°C surface temperature)
  • IECEx Certification: Compliant with IEC 60079 series

📻 DMR Digital Technology Advantages

The MOTOTRBO DMR Tier II platform provides significant advantages over traditional analog radios:

Feature DMR Digital Analog
Audio Quality Crystal clear, noise-free Static, interference
Spectrum Efficiency 2 voice paths per 12.5kHz channel 1 voice path per 12.5kHz channel
Battery Life Up to 40% longer Standard
Coverage Extended range Standard
Data Capabilities Text messaging, GPS, telemetry Voice only
Encryption Built-in digital encryption Limited/None
Call Features Private, group, all-call, emergency Basic group calls

🔊 Exceptional Audio Performance

In noisy industrial environments, clear communication can be the difference between safety and disaster. The XiR P8608Ex features:

  • Intelligent Audio technology that automatically adjusts volume based on ambient noise
  • Advanced noise cancellation for clear voice transmission even in high-noise areas
  • Powerful 1W speaker for loud, clear audio output
  • Digital audio processing eliminates static and distortion
  • Wind noise reduction for outdoor use

🔋 Extended Battery Life

The P8608Ex is optimized for long shift operations in demanding environments:

  • ATEX-certified battery designed for hazardous areas
  • Up to 28 hours of operation on a single charge (typical duty cycle)
  • Intelligent battery management extends overall battery lifespan
  • Battery status indicator shows remaining capacity
  • IMPRES battery technology (optional) for optimized charging and real-time battery diagnostics

💪 Rugged Construction

Built to survive the harshest industrial conditions:

Specification Rating
Ingress Protection IP67 (dust-tight, waterproof to 1m for 30 min)
Military Standard MIL-STD-810 C/D/E/F/G
Drop Resistance 1m drop onto concrete
Operating Temperature -30°C to +60°C
Humidity 95% non-condensing
Vibration/Shock Tested per MIL-STD specifications

📍 Integrated GPS (Model Dependent)

Select models include integrated GPS for location tracking:

  • Real-time location reporting for worker safety monitoring
  • Man-down detection triggers automatic GPS location alert
  • Lone worker function with GPS coordinates
  • Geofencing for area access control
  • Emergency location transmitted with alarm activation

🔐 Enhanced Security Features

Protect your communications with built-in security:

  • Digital encryption (ARC4 40-bit standard / AES 256-bit optional)
  • Authentication prevents unauthorized radio cloning
  • Remote radio disable/enable for lost or stolen units
  • Stun/Revive function for radio management
  • Secure boot ensures firmware integrity

Key Features & Specifications

Communication Features

Feature Description
Frequency Band UHF: 403-470 MHz
Channel Capacity Up to 1000 channels
Zone Capacity Up to 128 zones
Digital Protocol DMR ETSI TS 102 361-1, -2, -3
Operating Modes Digital, Analog, Mixed Mode
Power Output High: 4W / Low: 1W
Modulation Digital: 4FSK / Analog: FM
Channel Spacing 12.5kHz (digital/analog) / 25kHz (analog)

Call Features

Feature Availability
Group Call
Private Call
All Call
Emergency Call
Remote Monitor
Priority Interrupt
Call Alert
Radio Check
Radio Enable/Disable
Lone Worker
Man Down ✅ (with sensor)

Signaling Features

Feature Details
CTCSS 50 tones
DCS 104 codes
Analog Signaling MDC1200, 5-Tone, 2-Tone
Digital Signaling DMR standard signaling
VOX Hands-free voice activation
Scan Priority scan, vote scan

Safety Features

Feature Description
Emergency Button One-touch emergency activation
Emergency Alert Voice, data, or silent alarm options
Man Down Automatic alert when radio tilts or is motionless
Lone Worker Periodic check-in requirement with escalation
GPS Location Transmits coordinates with emergency
Intrinsically Safe Design Certified for explosive atmospheres

Display & Interface

Feature Description
Display Monochrome LCD (some models)
User Interface Programmable buttons, rotary channel selector
Indicators LED status indicator (tricolor)
Audio Internal speaker, 3.5mm accessory jack
Connector Multi-pin accessory connector

Physical Specifications

Specification Measurement
Dimensions Approx. 137 x 57 x 42 mm (H x W x D)
Weight Approx. 380g (with battery)
Antenna Stubby UHF antenna (ATEX certified)
Display Model dependent
Keypad Limited keypad / No keypad (model dependent)

ATEX Certification Explained

What is ATEX?

ATEX derives from the French “ATmosphères EXplosibles” and refers to two European Union directives controlling equipment and protective systems intended for use in potentially explosive atmospheres:

  1. ATEX 137 (Directive 99/92/EC): Minimum requirements for worker safety in explosive atmospheres
  2. ATEX 95 (Directive 2014/34/EU): Equipment and protective systems for use in explosive atmospheres

ATEX Zone Classification

The ATEX directive classifies hazardous areas into zones based on the frequency and duration of explosive atmosphere occurrence:

Gas/Vapor Zones:

Zone Definition Equipment Category Required
Zone 0 Explosive atmosphere present continuously or frequently Category 1G
Zone 1 Explosive atmosphere likely to occur during normal operations Category 2G
Zone 2 Explosive atmosphere unlikely, but possible for short periods Category 3G

Dust Zones:

Zone Definition Equipment Category Required
Zone 20 Combustible dust cloud present continuously or frequently Category 1D
Zone 21 Combustible dust cloud likely to occur occasionally Category 2D
Zone 22 Combustible dust cloud unlikely, but possible briefly Category 3D

XiR P8608Ex ATEX Rating

The Motorola XiR P8608Ex is certified as:

Ex ia IIC T4 Gb Ex ia IIIC T135°C Db

Breakdown:

Marking Meaning
Ex Equipment certified for explosive atmospheres
ia Intrinsically safe protection (highest level)
IIC Gas group – suitable for Hydrogen, Acetylene, and all less hazardous gases
T4 Temperature class – max surface temp 135°C
Gb Equipment Protection Level – suitable for Zone 1 and Zone 2
IIIC Dust group – suitable for conductive dust
T135°C Maximum surface temperature for dust
Db Dust protection level – suitable for Zone 21 and Zone 22

Why Intrinsically Safe?

Intrinsic safety (Ex ia) is a protection technique that limits electrical and thermal energy to levels below those that can cause ignition. This means:

  • No sparks – Electrical circuits designed to prevent ignition-capable sparks
  • Low energy – Energy levels too low to ignite explosive mixtures
  • Controlled temperature – Surface temperatures kept below ignition point
  • Fault tolerant – Safe even with two simultaneous faults
  • No enclosure needed – Protection is inherent in the circuit design

Industry Applications

The Motorola XiR P8608Ex is essential for organizations operating in hazardous environments across multiple industries:

🛢️ Oil & Gas Industry

Application Use Case
Upstream Operations Drilling rigs, wellhead operations, exploration sites
Midstream Operations Pipeline monitoring, pumping stations, gas processing
Downstream Operations Refineries, storage terminals, distribution facilities
Offshore Platforms Production platforms, FPSOs, support vessels
LNG Facilities Liquefaction plants, storage, regasification terminals

Key Benefits for Oil & Gas:

  • Zone 1 rated for refinery process areas
  • GPS tracking for remote wellsite workers
  • Man-down detection for lone workers
  • Emergency alarm with location data
  • Integration with plant-wide communication systems

⛏️ Mining Industry

Application Use Case
Underground Mining Coal mines, metal ore extraction, tunnel operations
Surface Mining Open pit operations, processing plants
Processing Facilities Crushing, milling, flotation, smelting
Storage & Transport Coal bunkers, conveyor systems, loading facilities

Key Benefits for Mining:

  • Dust zone certification (Zone 21/22) for coal and metal dust
  • Rugged construction for underground conditions
  • Long battery life for extended shifts
  • GPS for above-ground location tracking
  • Emergency communication in remote locations

🧪 Chemical & Petrochemical Industry

Application Use Case
Chemical Manufacturing Reaction vessels, distillation, storage
Petrochemical Plants Ethylene crackers, polymerization units
Specialty Chemicals Pharmaceutical intermediates, fine chemicals
Fertilizer Production Ammonia plants, urea facilities

Key Benefits for Chemical Industry:

  • IIC gas group rating for hydrogen and acetylene compatibility
  • T4 temperature class for most chemical processes
  • Digital encryption for sensitive operations
  • Integration with plant emergency systems
  • Clear audio in high-noise process environments

💊 Pharmaceutical Industry

Application Use Case
Active Ingredient Production API manufacturing, solvent handling
Formulation & Filling Dust-generating operations
Cleanroom Adjacent Areas Areas near solvent storage
Warehouse & Distribution Flammable material storage

Key Benefits for Pharmaceutical:

  • Zone 21/22 dust certification for powder handling
  • Easy to clean and sanitize exterior
  • Private call capability for confidential communication
  • Compliance support for GMP environments

🌾 Grain & Food Processing

Application Use Case
Grain Elevators Receiving, drying, storage, loading
Flour Mills Milling, packaging, storage
Sugar Refineries Processing, drying, packaging
Food Processing Spray drying, dust-generating operations

Key Benefits for Grain/Food:

  • Dust zone certification critical for grain dust explosions
  • IIIC rating for conductive (metal) dust compatibility
  • Durable construction for harsh agricultural environments
  • Group communication for coordinated operations

⚡ Utilities & Power Generation

Application Use Case
Natural Gas Distribution Metering stations, pressure reduction facilities
Power Plants Coal-fired plants, gas turbine facilities
Biogas Facilities Digesters, gas storage, upgrading plants
Hydrogen Production Electrolysis plants, storage facilities

Key Benefits for Utilities:

  • Zone 1/2 rating for gas handling areas
  • Long-range communication for utility corridors
  • GPS tracking for field service crews
  • Emergency response coordination

🎨 Paint & Coatings Industry

Application Use Case
Paint Manufacturing Mixing, milling, tinting
Industrial Coating Spray booths, drying ovens
Automotive Plants Paint lines, preparation areas

Key Benefits for Paint/Coatings:

  • Solvent vapor zone certification
  • Compact design for spray booth operations
  • Clear communication in ventilated areas

XiR P8608Ex vs. Standard Radios

Feature XiR P8608Ex (ATEX) Standard Two-Way Radio
Hazardous Area Use ✅ Zone 1, Zone 2, Zone 21, Zone 22 ❌ Not permitted
Intrinsically Safe ✅ Ex ia certification ❌ No
ATEX Certified ✅ Yes ❌ No
IECEx Certified ✅ Yes ❌ No
Spark Prevention ✅ Designed to eliminate ignition sources ❌ Standard electronics
Temperature Control ✅ Limited surface temperature ❌ No control
Battery ✅ ATEX-certified battery ❌ Standard battery
Accessories ✅ Must be ATEX-certified ❌ Standard accessories
Use in Refineries ✅ Permitted ❌ Prohibited
Use in Chemical Plants ✅ Permitted ❌ Prohibited
Use in Mines ✅ Permitted ❌ Prohibited
Cost $$$$$ $$

⚠️ IMPORTANT SAFETY NOTICE: Using non-certified equipment in hazardous areas is illegal and extremely dangerous. Standard radios can cause explosions resulting in death, injury, and property destruction. Always use properly certified ATEX/IECEx equipment in explosive atmospheres.


Motorola XiR P8608Ex System Compatibility

The XiR P8608Ex integrates seamlessly with Motorola’s MOTOTRBO ecosystem:

Compatible Infrastructure

System Compatibility
MOTOTRBO Repeaters SLR 5500, SLR 8000 series
IP Site Connect Multi-site wide-area coverage
Capacity Plus Single-site trunking
Capacity Max Multi-site trunking
Connect Plus Multi-site trunking
WAVE PTT Broadband PTT integration

Compatible Portable Radios

The P8608Ex works alongside other MOTOTRBO portables:

  • XiR P8668 / P8660 (standard, non-ATEX)
  • XiR P8628 / P8620
  • XiR P6600 series
  • DP4800 / DP4600 series
  • SL series (Slim radios)

Compatible Mobile Radios

  • XiR M8668 / M8660
  • XiR M8628 / M8620
  • DM4600 / DM4601

Package Contents

Standard Package Includes:

Item Quantity Certification
Motorola XiR P8608Ex Radio 1 ATEX/IECEx Certified
ATEX Certified Li-ion Battery 1 ATEX/IECEx Certified
ATEX Certified UHF Antenna 1 ATEX/IECEx Certified
Belt Clip 1 ATEX/IECEx Certified
Dust Cover 1
User Documentation 1
Safety Information 1

Charger (Sold Separately or Bundled):

Item Description
Single-Unit Charger IMPRES or standard charger for single radio
Multi-Unit Charger 6-unit charger for fleet charging

⚠️ Note: Charging must be performed in safe areas only. ATEX batteries must never be charged in hazardous locations.


ATEX Certified Accessories

All accessories used with the XiR P8608Ex in hazardous areas must also be ATEX certified. Available accessories include:

Audio Accessories

Accessory Description ATEX Zone
ATEX Earpiece Receive-only earpiece Zone 1/21
ATEX Remote Speaker Mic Speaker microphone Zone 1/21
ATEX Headset Over-the-head or hard hat mount Zone 1/21
ATEX Bone Conduction Headset For high-noise environments Zone 1/21

Power Accessories

Accessory Description Notes
ATEX Battery Spare Li-ion battery Required for Zone 1/21
Single-Unit Charger Desktop charger Safe area use only
Multi-Unit Charger 6-bay charger Safe area use only
Vehicle Charger 12V vehicle charging Non-hazardous vehicles

Carry Accessories

Accessory Description ATEX Zone
Belt Clip Spring-action clip Zone 1/21
Leather Carry Case Protective holster Zone 1/21
Chest Harness Hands-free carry Zone 1/21

Programming & Data

Accessory Description Notes
Programming Cable USB connection to PC Safe area use only
CPS Software Customer Programming Software Radio programming

⚠️ WARNING: Using non-ATEX-certified accessories in hazardous areas voids certification and creates explosion risk. Always verify accessory certification before use in Zone 1/2/21/22 areas.


Wholesale & Enterprise Solutions

We provide comprehensive solutions for enterprise and industrial customers:

Volume Pricing

Order Quantity Discount Level
1-4 units Standard Price
5-9 units 5% Off
10-24 units 10% Off
25-49 units 15% Off
50+ units Contact for Custom Quote

Enterprise Services

Service Description
Fleet Programming Pre-configured radios ready to deploy
Frequency Coordination Assistance with frequency licensing
System Design Coverage planning and system architecture
Installation Support Technical guidance for system deployment
Training User and administrator training
Extended Warranty Additional coverage options
Maintenance Contracts Ongoing support and service

Rental Programs

For short-term projects or trials:

  • Daily, weekly, or monthly rental
  • ATEX-certified rental fleet available
  • Accessories included
  • Technical support during rental period

Compliance & Documentation

Certifications Held

Certification Standard Status
ATEX Directive 2014/34/EU ✅ Certified
IECEx IEC 60079 series ✅ Certified
CE Marking EU Conformity ✅ Compliant
FCC Part 90 ✅ Approved
IC Canada ✅ Approved
MIL-STD-810 US Military Standard ✅ Tested
IP67 Ingress Protection ✅ Rated

Documentation Available

Document Description
ATEX Certificate Official ATEX certification document
IECEx Certificate International certification document
Declaration of Conformity EU DoC for CE marking
User Manual Operating instructions
Safety Manual Hazardous area usage guidelines
Programming Guide CPS software instructions
Technical Data Sheet Detailed specifications

Frequently Asked Questions (FAQ)

Q: What hazardous zones is the XiR P8608Ex approved for?

A: The Motorola XiR P8608Ex is ATEX certified for Zone 1 and Zone 2 (gas/vapor) and Zone 21 and Zone 22 (dust) hazardous areas. It is not certified for Zone 0 or Zone 20 (continuous explosive atmosphere).

Q: Can I use standard Motorola accessories with the P8608Ex in hazardous areas?

A: No. In hazardous areas, you must only use ATEX-certified accessories. Using non-certified accessories voids the intrinsically safe certification and creates serious explosion risks. Standard accessories may only be used in safe (non-hazardous) areas.

Q: Can I charge the ATEX battery in a hazardous area?

A: No. ATEX-certified batteries must only be charged in designated safe areas. Charging in hazardous areas is prohibited and dangerous. Chargers are not intrinsically safe devices.

Q: Is the XiR P8608Ex compatible with my existing MOTOTRBO system?

A: Yes, the XiR P8608Ex is fully compatible with MOTOTRBO DMR Tier II infrastructure including repeaters, IP Site Connect, Capacity Plus, Capacity Max, and Connect Plus systems. It can operate alongside standard (non-ATEX) MOTOTRBO radios in the same system.

Q: What is the difference between XiR P8608Ex and XiR P8668Ex?

A: Both are ATEX-certified DMR radios. The P8668Ex typically includes additional features such as a full keypad, larger display, GPS, and Bluetooth as standard. The P8608Ex is a more basic model with limited or no keypad, optimized for users who need simple, reliable communication. Verify exact features with your supplier as configurations vary by region.

Q: Can the P8608Ex communicate with analog radios?

A: Yes, the XiR P8608Ex supports mixed mode operation, allowing it to communicate with both DMR digital radios and legacy analog radios on the same channel. This enables phased migration from analog to digital systems.

Q: What is the actual communication range?

A: Range depends on many factors including terrain, infrastructure, and operating environment. With a repeater system, coverage can extend across an entire facility or multiple sites. In direct (simplex) mode, typical range is 1-5km depending on conditions. Indoor range in industrial facilities varies based on building construction.

Q: Do I need a license to operate the XiR P8608Ex?

A: Yes, the XiR P8608Ex operates on licensed UHF frequencies. You must obtain appropriate radio licenses from your national telecommunications authority (e.g., FCC in USA, Ofcom in UK, ACMA in Australia). License requirements vary by country.

Q: What warranty is provided?

A: Motorola provides manufacturer warranty covering defects in materials and workmanship. Extended warranty and service contract options are available. Contact us for specific warranty terms in your region.

Q: How do I program the radio?

A: The XiR P8608Ex is programmed using Motorola CPS (Customer Programming Software) connected via USB programming cable. Programming must be done in a safe (non-hazardous) area. We offer fleet programming services for bulk orders.

Q: Is training available for using ATEX radios?

A: Yes, we recommend training for both users and administrators. Training covers safe operation in hazardous areas, proper accessory use, charging procedures, and emergency functions. Contact us for training options.


Safety Warnings

⚠️ CRITICAL SAFETY INFORMATION:

  1. Use Only in Rated Zones: The XiR P8608Ex is certified for Zone 1/2/21/22 only. DO NOT USE in Zone 0 or Zone 20 (continuous explosive atmosphere).
  2. ATEX Accessories Only: In hazardous areas, use ONLY ATEX-certified accessories. Standard accessories are prohibited and dangerous.
  3. Safe Area Charging: Batteries must ONLY be charged in safe (non-hazardous) areas. Never charge in or near explosive atmospheres.
  4. Battery Integrity: Do not use batteries that are damaged, leaking, or modified. Replace damaged batteries immediately.
  5. No Field Repairs: Do not attempt to repair or modify the radio. All service must be performed by authorized personnel in safe areas.
  6. Follow Local Regulations: Comply with all local safety regulations and site-specific procedures for equipment use in hazardous areas.
  7. Regular Inspection: Inspect radio and accessories regularly for damage. Damaged equipment must not be used in hazardous areas.
  8. Turn Off Before Removing Battery: Always turn off the radio before removing the battery to prevent potential sparking.
  9. Report Defects: Immediately report any equipment defects to your safety officer and remove from service.
  10. Training Required: Ensure all users are trained in safe operation of intrinsically safe equipment.

FAILURE TO FOLLOW THESE SAFETY REQUIREMENTS CAN RESULT IN EXPLOSION, FIRE, DEATH, OR SERIOUS INJURY.

 

300300300300

Shopping Cart
Scroll to Top